HDI PCB Build-Ups Explained — 1+N+1, 2+N+2 and Any-Layer

hdi pcb build up structures hero 1

What an HDI PCB Build-Up Tells You

In a high-density interconnect (HDI) PCB build-up, the layers added on each side determine which layers a microvia can reach beneath a ball grid array (BGA). A 1+N+1 board adds one layer per side. A 2+N+2 board adds two. Any-layer HDI allows microvia connections throughout the stack. Each extra build-up stage opens more routing paths and adds drilling and lamination costs.

Read the notation from the top surface to the bottom. N counts the copper layers in the central section, which may itself be a multilayer board. The numbers outside N count the build-up layers on its two faces. For example, 1+6+1 and 2+4+2 both give you eight copper layers. The difference is where a signal can change layers beneath the package.

hdi pcb build up structures 1+n+1 2+n+2 any layer cross section

HDI structures compared for the same board outline and order quantity

Build-upRelative lamination cyclesTypical via structureTypical useRelative cost
1+N+1One build-up stage around the prepared centerBlind microvia from each outer face to its nearest inner layerBGA signals can leave the pad field on the surface or next layerUsually lowest of the three
2+N+2Two successive build-up stages around the prepared centerTwo microvia levels per side, staggered or stacked where connectedInner ball rows need access to a deeper routing layerUsually higher than 1+N+1
Any-layer (ELIC)Repeated stages through the stack. The count depends on the construction.Copper-filled microvias between adjacent layers can form longer pathsConnections must change layers at several depths in a tight areaTypically highest for a comparable board

The cycle column counts the added HDI stages in a conventional symmetric build. The fabricator can build both faces in the same stage. Making the center, especially if it contains buried vias, can add press operations to the full process. Ask which operations a supplier includes when it quotes a cycle count.

How a 1+N+1 HDI Stackup Routes a BGA

Picture a 1+6+1 board with its copper layers labeled L1 at the top through L8 at the bottom. The six-layer center runs from L2 through L7. A top-side microvia connects L1 to L2. Its bottom-side counterpart connects L8 to L7. A signal from a BGA pad can drop to L2 and run sideways, leaving space on L1 for another trace.

This works when the signal can actually leave the package area on its assigned layer. L2 may already be a continuous ground plane, or the available routing channel may end at a row of power vias. Draw the path past the edge of the BGA. If it reaches a less crowded area there, a through via farther out can take the signal deeper without using space between the balls.

What a 2+N+2 HDI Structure Adds

In an eight-layer 2+4+2 board, the center runs from L3 through L6. On the top side, the fabricator forms the L2-to-L3 connection before adding the outer layer and making the L1-to-L2 connection. The corresponding bottom-side spans are L7 to L6 and L8 to L7. The extra stage lets a signal reach L3 while it is still inside the BGA footprint.

There are two common ways to join those top-side spans. Staggered microvias land at different positions on L2, where a short copper connection joins them. That connection needs room beside the pad. Stacked microvias line up vertically, saving space on L2. The lower microvia typically needs a filled, flat copper landing for the one above it. A drawing should identify where stacking is necessary so the fabricator can quote the intended construction.

How Any-Layer HDI (ELIC) Connects Inner Layers

Every-layer interconnection (ELIC) lets the designer use microvias between neighboring copper layers throughout the board. In its any-layer HDI process, AT&S uses a laser to drill these connections. To connect more distant layers, the layout joins the required spans, often by stacking copper-filled microvias. Each connection ends where the circuit needs it. A signal can leave the via stack on an inner layer while other nets use the space beneath it.

That flexibility matters when several dense packages compete for the same routing space. For example, two devices mounted on opposite faces may each need local access to inner signals. Map their escape paths together. If the remaining conflict is confined to one pin group, a placement change may resolve it. If connections need to cross several inner interfaces throughout the layout, an any-layer HDI PCB is worth quoting.

How to Choose the Lowest-Cost Build-Up for Your BGA Pitch

BGA pitch is the distance between adjacent ball centers. It sets the available space, but the ball map determines what must pass through that space. In Figure 16 of its flip-chip BGA package guide, Texas Instruments shows a 0.8 mm (about 31.5 mil) pitch example. The outer two signal rows escape on the top layer. Blind microvias take the next two rows to the second layer. That result applies to the pad arrangement and routing geometry shown.

  1. Mark the balls that need a route. Start with the actual package ball map and pin assignments. Identify signal groups, supply pins, ground pins, and unused positions. An empty region in the array can provide an escape path that a fully populated package would block.
  2. Try the shallowest practical escape. If the ball map has open channels, try through vias first. Then test a single microvia level where through-via pads block the route. Use the proposed pad sizes and clearances. Include power connections and the reference plane for each critical signal. Benlida’s HDI PCB design rules explain the geometry to discuss with the fabricator.
  3. Identify the blocked connection. If L1 and L2 run out of room, try the same group with access to L3. Check whether a staggered pair fits or the route needs a stack. Mark the specific layer spans that solve the problem.
  4. Request quotes for the layouts that work. Give each supplier the same outline, finished thickness, quantity, copper requirements, and electrical targets. Ask what changes in fabrication, test coverage, and price between those versions. A simpler build that forces finer tracks elsewhere may lose its expected cost advantage.

What Laser Drilling, Via Fill, and Registration Change in Manufacturing

During sequential lamination, each new dielectric layer covers a copper target pad. A laser opens the dielectric to that pad. The fabricator cleans the opening and deposits a conductive coating. Copper plating then forms the electrical connection. Once the next layer covers this interface, its position and condition matter to every microvia that lands above it. The Sierra Circuits HDI stackup guide shows how the build-up stages relate to the via spans.

hdi microvia cross section

Registration is the alignment of each opening to the pad beneath it. A cross-section can show where the opening landed and how the copper fill meets the target pad. Distinguish a copper-filled laser microvia from a plated through hole specified for resin via filling. In a resin-filled plated hole, the copper wall provides the electrical path. The PCB via types guide can help you label the different holes on the drawing.

A stacked structure also needs a sound copper interface through assembly temperatures. IPC’s microvia reliability warning describes weak interfaces that can open during solder reflow and escape detection at room temperature. For a critical stack, ask what test coupon represents the proposed spans and whether the fabricator monitors its electrical continuity through a representative thermal cycle.

Send your HDI stack-up for review with the package ball map, a layer-by-layer drawing, and the Gerber or ODB++ and drill files available for that revision. Mark which vias must stack and which may move. This gives Benlida’s HDI PCB manufacturing team the details needed to compare feasible builds.

FAQ

What does 1+N+1 mean in HDI PCB?

It means one build-up layer on each side of a central section with N copper layers. In a 1+6+1 design, the finished board has eight copper layers. A typical top-side microvia spans L1 to L2. Any deeper connection needs a separate via path defined in the stackup.

What is the difference between 2+N+2 and any-layer HDI?

A 2+N+2 board provides two build-up levels on each side of its center. An any-layer board supports microvia connections across adjacent layers throughout the stack. Choose between them by identifying the deepest transitions your signals need and checking where the required landing pads fit.

Which HDI build-up is cheapest?

For comparable designs, 1+N+1 usually costs least because it needs fewer build-up stages. The lowest-cost option for your board also depends on the routing geometry, board area, and order quantity. Compare quotes for layouts that meet the same electrical and mechanical requirements.

How many layers can an HDI PCB have?

The HDI label gives no fixed layer count. An eight-layer board, for example, can use either 1+6+1 or 2+4+2. The feasible count for your project depends on the finished thickness, materials, via spans, and the construction your fabricator can qualify. Include those details when requesting a quote.

Planning an HDI Board?

Benlida’s engineers review your build-up and suggest the most cost-effective structure with a free DFM review.